Experimental method

Comparison of initial capacity

By combing with graphene, the initial capacity of the cathode was 1.5 times higher than that without graphene.

Active material Active material: Conductive agent: Binder = 80: 10: 10
counter electrode Lithium metal
Electrolyte

1M LiPF6, EC/DEC no additive

Current rate

0.1C

Comparison of discharge rate performances with and without graphene

Discharge rate performance from 0.5C to 50C

Cycle performance at Room temperature (1C)